Alkane Toolkit

Scanning

Discovery is read-only: a scan asks each address what it is and records what it reports. It never changes a miner.

Scan ranges

Click Scan ranges to edit the addresses to scan. Put one entry per line; blank lines and lines starting with # are ignored.

Form Example Scans
Single address 192.168.1.50 that address
CIDR block 192.168.1.0/24 the whole block
Full range 192.168.1.10-192.168.2.40 every address between the two, inclusive
Short range 192.168.1.10-90 .10 to .90 within the same /24
Per-octet ranges 10.1-4.0-1.1-255 every combination (10.1.0.1 ... 10.4.1.255)

Commas or spaces between several entries on one line are not accepted; use one line each. Duplicates are removed automatically. One line, and all lines together, may cover at most 1,000,000 addresses.

Apply saves the ranges and starts a scan. A mistake keeps the dialog open and the status bar explains it, for example invalid range: bad octet range.

The same dialog has three numbers:

Field Meaning Default
Rescan (s) seconds between automatic rescans; 0 turns auto-rescan off 300
Timeout (s) how long to wait for one miner (scans, refreshes, actions and log fetches) 10
Concurrency how many addresses are probed at once (8 to 256); higher is faster but slow miners may report fewer values 128

When the ranges change, miners outside the new ranges leave the table at the next scan.

Running, pausing and stopping

The three buttons next to Scan ranges control scanning:

  • Play (green) turns auto-rescan on and starts a scan now if none is running.
  • Pause (amber) turns auto-rescan off and lets the current scan finish.
  • Stop (red) turns auto-rescan off and cancels the current scan.

While a scan runs, a progress bar spans the top of the table and the status bar shows progress such as 1935/4590 - scanning 192.168.1.86 (92 found). Afterwards it shows the count and the time to the next scan, for example 245 miners - next scan in 4m 12s.

Actions that change miners wait for the scan to finish; see Actions.