6fb73c97462dd3e31e646e1005cca719c0f1663f
18
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
49985631d4 |
antminer: read best-share fleet-wide + Bixbit "Power Estimated" wattage (R7)
Round 17 R7. Flashing Bixbit onto fleet units surfaced two Antminer scan gaps (patch 0019): the stock v2023_07 backend never fetched best-share at all (DataField::BestShare had no source), so it was blank for every stock/Bixbit Antminer; and it read wattage only from the cgminer stats, which Bixbit-based firmware leaves at 0 (real draw is in the summary as "Power Estimated"). Now maps BestShare/SessionBestShare to the cgminer summary and adds a "Power Estimated" wattage fallback (stock power still wins when present). Verified live: Bixbit S19j Pro (10.4.1.70) now reads 2615 W + best-share 178930671; stock S21 Pro (10.4.1.90) now reads best-share 299464394 -- both were blank before. 36 antminer backend tests + SELFTEST pass, no wattage regression. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
8fe61ec427 |
psu: PSU info scan + version/Vmin/Vmax columns + tooltip V/A (R5/G15)
Round 17 R5/G15. asic-rs had no PSU telemetry. Adds an optional PsuInfo to MinerData (model, version, rated voltage min/max, live output voltage/current), a DataField::Psu, and a default parse_psu backends override (patch 0018). ePIC populates it by merging the summary "Power Supply Stats" with the capabilities "Psu Info". GUI: three new columns -- "PSU version", "PSU Vmin", "PSU Vmax" (Hardware group in the picker) -- and the R2 power tooltip now shows the PSU output voltage (and amperage when the firmware reports a non-zero current; ePIC leaves current 0, so it shows just the voltage). Verified live on ePIC S19j Pro (10.4.1.6/.10): model 117, fw 22, Vmin 11.877 V, Vmax 15.182 V, output ~13.2 V. 8 model tests + 18 ePIC backend tests + SELFTEST pass. Non-ePIC firmware leave the PSU fields blank until they add parse_psu. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
08b3d56864 |
luxminer: set power-limit profile by name so the default profile is reachable
Round 17 C, found via live tuning verification. LuxOS set_power_limit mapped
watts to a profile but applied it by the profile's Step. The factory "default"
profile has Step "0", which LuxOS profileset reads as an empty parameter
("Missing profile parameter"), so the setter could never select the default and
a miner nudged off it by a watts limit could not be returned to its factory
point. Key on the profile Name instead (patch 0017).
Verified live on a LuxOS S19j Pro (10.4.1.60): set_power_limit(2700)->480MHz/2632W,
set_power_limit(2900)->default/2794W (previously errored). Unit test updated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6
|
||
|
|
da0d1582be |
scan: cap identification concurrency at 128 to fix Braiins value dropout (R4)
Round 17 R4. Scanning most values from Braiins OS units failed under a full fleet scan: a /24 returned watts=0 and no best-share/temps/fw for Braiins miners (and dropped a few responders entirely), while the same miner scanned in isolation populated fully. Root cause: asic-rs picks a scan concurrency of 1000 for any range up to /22, so a /24 fires all ~254 address probes at once. Over a real link (the fleet is reached across a WireGuard VPN, and a subnet full of dead IPs holds every TCP connect open for the whole identification timeout) that burst starves the per-responder get_data. A Braiins miner fans out ~12 authenticated REST calls; under the burst they drop miner/stats, so "most values" come back blank. It is not FD exhaustion (nofile is 500k), not the per-call timeout, and not an auth race. Fix: cap identification concurrency at 128 in the app (GUI scan + miner_probe). On the live fleet 128 was the highest cap that stayed fully reliable -- 192 already dropped responders, 254 blanked a Braiins miner. A /24 still finishes in ~35s; larger ranges just take proportionally longer and stay correct. Belt-and-suspenders in the braiins backend (patch 0016): single-flight the login (one auth instead of ~12 concurrent) and widen the defensive get_data timeout 5s -> 15s. Verified live: 10.4.1.0/24 now populates both Braiins corpus miners (.27 watts=2748 best=55217110, .83 watts=2749) fully and misses no responders (65/65). SELFTEST PASS. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
86338062a5 |
Round 17 B (part 2, GUI): timezone / change-password / factory-reset dialogs + BOS fix
Wire G10/G11/G12 into the GUI (they already had CLI verbs in part 1): - MinerCaps gains timezone / change_password / factory_reset (probed from the matching supports_*() at scan time; intersect + any_control + is_empty updated). - ConfigAction gains Timezone(String) / ChangePassword(String) / FactoryReset with labels + apply arms. Timezone/FactoryReset go through apply_action(&dyn Miner); ChangePassword takes &mut self so it runs on the owned miner in the action loop. - ui.rs: a shared PromptKind (Power/Tuning/Timezone/Password) generalises the value prompt (timezone is IANA-validated before firing; password is non-empty); factory-reset uses the confirm dialog with a strong WIPES-config/DHCP warning. New gated context-menu items: Set timezone, Change password, Factory reset. Backend fix (asic-rs patch 0015): BOS send_command treated an empty 2xx body as a parse error, so change_password reported Ok(false) on success. Empty 2xx is now Null (success). Found + fixed while live-verifying G11. Verified live on Braiins 10.4.1.27: full change-password round-trip (root -> bftest2 -> read with new pw -> restore root), all Ok(true), unit left on root/root. Timezone shares the CLI-verified set_timezone_config path. Factory-reset is wired + gated but intentionally NOT live-fired: its behaviour is unrecoverable per firmware (can revert LuxOS to stock / reset network to DHCP and lose the unit) -- needs a truly sacrificial console-attached unit. GUI selftest + 89 unit tests pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
25c8ccf1ff |
Round 17 A (part 2, G13): LuxOS pool ops privileged + removepool
The luxminer pool write commands (addgroup/groupquota/removegroup/addpool/ switchpool/enablepool/disablepool) sent privileged=false -> no session_id, which fails with "Missing session_id" on password-set LuxOS units (all other LuxOS writes are already privileged). Flipped all seven to privileged=true and added the missing removepool. asic-rs patch 0014. Verified no regression on default corpus unit 10.4.1.60 (set_pools_config still applies). The password-set failure needs a password-set LuxOS unit to verify live. Round A remaining: G8 (constraints/limits reads) and G14 (telemetry enrichment) are deferred to the rounds that consume them (G8 -> the tuning/cooling dialogs in C/D; G14 -> detail-panel/tooltip work) rather than built as unused plumbing now. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
307539543d |
Round 17 A (part 1): committed write CLI (G1) + best-share reads (G9) + parity roadmap
Executing the aftermarket config+scan parity plan (docs/aftermarket-parity-roadmap.md, from the ultracode writer/adversary workflow). This is Round A's foundation + first cheap win. G1 - miner_probe is now a committed config+scan CLI, not a local-only diagnostic. Added capability-gated write verbs: `light <ip> <on|off>`, `pause`, `resume`, `restart` (alongside the existing setpl/setpools/led), a READ vs WRITE usage banner warning that write verbs mutate (use the test-bed miners, not production), and best_share/session_best_share columns in `scan`. Verified: `light on`/`light off` on a LuxOS corpus unit -> Ok(true) (reversible). G9 - implement GetBestShare/GetSessionBestShare (were empty impls feeding two dead columns): Braiins v26_04 reads miner/stats -> /miner_stats/best_share; LuxMiner v1 reads summary -> /SUMMARY/0/Best Share + Best Session Share. Both reuse already-collected responses (no extra calls). asic-rs patch 0013. Verified live read-only: BOS 10.4.1.83 = 130601978 (no session on BOS); LuxOS 10.4.1.60 = 638881749/638881749, 10.4.1.67 = 497802665/497802665 -- exact API match. (WhatsMiner stock summary exposes no best-share on the tested units; deferred. The roadmap's BOS source "miner_stats" was a typo for the real "miner/stats" endpoint.) Also commits the parity roadmap (docs/) as the plan of record for rounds A-F. Round A remainder (G8 constraints reads, G13 LuxOS pool-op privileged fix, G14 telemetry enrichment) follows; G13 needs a password-set LuxOS unit to fully verify. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
74b97162f5 |
GUI round 16 (#1/#2/#3): per-component health attribution + tooltips
Health icons and their hover tooltips now reflect the miner's actual per-component faults instead of a generic "faulted". - #1 Each Health icon's tooltip carries the specific fault text for THAT component (e.g. "Slot 0 error reading chip id.", "Power current error."), sourced from asic-rs's structured MinerMessage.component (HashBoard idx / PowerSupply / Fan / ControlBoard) rather than fragile string matching on the summary. New MinerRow `faults` field + FaultComponent/Fault types; scan.rs maps messages -> faults. - #2 A power-supply fault turns the bolt icon red, lists the PSU faults on its tooltip, and greys (not reds) every hashboard -- the boards can't be powered or tested, so they read "unpowered (PSU fault)". - #3 When the miner reports board-specific faults, ONLY the named boards are red; the rest stay green. A whole-miner stall zeroes every board's hashrate, which previously reddened working boards the error codes actually exonerate. Backend enabler (asic-rs patch 0012): the WhatsMiner V1 backend now sources faults from get_error_code (like V2/V3; its summary error fields are empty on H6OS), and a targeted repair fixes firmware that emits an invalid bare-pair error_code array. Verified live: 10.7.1.231 (PSU) greys its boards + shows the 4 PSU faults on the bolt; 10.8.1.234 (540/541/561) reds boards 1+2 and leaves board 3 green. Unit tests cover the attribution and the malformed-array repair; all suites pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
75663f4c23 |
asic-rs: implement LuxOS set_power_limit (via profiles); document ePIC PSU gating
Follow-up to the Round 15 corpus. The toolkit reported supports_power_limit=false for LuxOS and ePIC; investigated both against the live corpus (S19j Pro). LuxOS was genuinely under-reporting: it tunes by discrete named profiles that each carry a Watts rating (the `profiles` RPC gives Step + Watts), applied via profileset -- pure frequency/voltage tuning, no PSU dependency. Implemented SetPowerLimit to map the requested watts to the highest profile whose Watts does not exceed it (or the lowest profile when the target is below all of them). The pure mapping (parse_profile_watts + select_profile_at_or_below) has a unit test. Live-verified: set_power_limit(2500) on an S19j Pro picked step -4 (2385 W) and the miner's active profile became 445MHz/-4. ePIC is left at false, now with a comment explaining why: PowerPlay's only true power-limit path is the PowerTune perpetual-tune algorithm, which the firmware gates on the PSU -- on a fixed-voltage Bitmain APW12 (S19j Pro) it answers "Power optimization is not supported by this PSU". That is a per-PSU runtime property the synchronous capability check cannot see, so reporting true would over-advertise on most reflashed Antminers. Hashrate tuning remains available via set_tuning_config. Captured as asic-rs patch 0011. luxminer + epic crate tests pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
9eb6a0f229 |
asic-rs: fix Antminer locate-LED (and reboot) on legacy web-UI firmware
Round 15 #7. The "flash the light" action failed on old (< 2023.07) Antminer firmware -- the LuCI web-UI generation, e.g. the Z15/Z15J. set_fault_light returned Ok(false) on live hardware while appearing to "succeed". Root cause (confirmed on a live Z15): that firmware's blink.cgi ignores the JSON body {"blink":"true"} the backend sent (answering 200 with an empty text/html body, so the JSON parse fails and the error is swallowed into Ok(false)). Its own blink.html POSTs a form field action=startBlink/stopBlink and reads state back via action=onPageLoaded -> {"isBlinking":bool}; the action handler also often answers 401/500 even on success, so HTTP status is not a reliable signal. Fix (v2020 backend): add a form-encoded POST helper; blink() now fires action=startBlink/stopBlink, ignores the unreliable status, and reads the real state back via onPageLoaded; set_fault_light reports success only when the observed isBlinking matches the request. The LightFlashing read is routed to the same path (get_blink_status.cgi is 404 here) and remapped to {"blink":bool}. Also switch reboot() from POST to GET to match the same firmware's reboot.html (the Restart action was affected); not live-fired, to avoid rebooting production miners. Captured as asic-rs patch 0010. Also teach ci/compute-version.sh that vendor/* and thirdparty/asic-rs/* are backend changes, so vendored fixes trigger a release. Verified live: Z15/Z15J now return Ok(true) with the light genuinely toggling; VNish (4 control boards) and WhatsMiner (H6OS/H616) unchanged; antminer tests pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
0d19e958f0 |
GUI round 15 (part 1): pool dropdowns, aligned health icons, export, more
Twelve of the round-15 items (the code items; the live-hardware flashing/ testing and the settings/localization/logs work follow separately): #1 Configure-pools: three pool rows (address, account, worker, password), each field with a "+" dropdown of presets (top-11 BTC pool stratums; worker-name placeholders) plus user-addable, persisted entries. Worker picks insert at the cursor rather than replacing. Writes up to three pools per miner via set_pools_config, worker expanded per unit. #2 PIC detection: replace the broken SSH i2cdump (it read 0x48, the temp sensor, not the PIC) with a model lookup -- no firmware exposes PIC over the network, so infer it from the model (noPIC: S19k Pro, S21 family, T21, explicit noPIC; PIC: rest of the S19 line). #4 Zoom: an editable percent field in the status bar (type an exact scale) and Ctrl +/- / Ctrl+0 to zoom in/out/reset. #5 Health icons align in fixed slots (power, control, fans, hashboards); miners with fewer fans/boards leave a gap so hashboards still line up. The max fan/board counts are computed parametrically from the fleet. #6 Light: the locate-light column is on by default (last), shown as a green-over-red beacon flashing quickly instead of a single amber dot. #8 The bottom-left status line is now scan-only; operation progress lives in the Health column (per miner) and failures in the bottom-right indicator. #9 / #10 / #11: drop the Credentials-dialog blurb; move the scan-ranges format help to a tooltip; make Restore-to-stock a plain confirmation (no typed keyword, no warning wall). #12 Z15 fans: the v2020 backend now reads fans from higher fan slots (the Z15 reports fan3/fan4 with fan1/fan2 = 0). Vendored patch 0009. #14 Export: an Export button writes every scanned data point to a CSV, one value per cell (lists expanded to indexed columns) -- complete and machine-readable, unlike the on-screen table. #15 Health tooltips are per-icon: hovering a specific fan or hashboard shows just that component's state, with errors attributed to the board that names them in the message. New wx-rs bridge surface: widget tooltips, save-file dialog, insert-at-cursor, status-bar zoom entry + Ctrl+/-, the light beacon + alignment-gap sentinels, and per-icon cell tooltips (bridge patches 0002/0003 regenerated). Unit tests (worker templates, PIC map, CSV export, health) + headless selftest pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
ecdb2fab9d |
GUI round 13: health-icon column, Z15J algorithm, Credentials + Columns dialogs
Five items from the round-13 list: #4/#5 Z15 hashrate / unknown algorithm: a Z15J reports its model as "ANTMINER Z15J", which asic-rs' alias table did not recognise, so it deserialised to Unknown and its Sol/s hashrate was left un-bucketed as "unknown hashrate". Add a first-class Z15J model (Equihash) in the makes crate, plus a family-letter fallback in the v2020 backend so other un-tabled Antminer models still resolve an algorithm (Z->Equihash, L->Scrypt, S/T->SHA-256; ambiguous K/DR stay Unknown). Live-verified on the Z15/Z15J fleet. Carried as vendored patch 0008. #3 Component-health column: a new Health column (power, control board, each fan front-to-back, each hashboard) drawn as coloured icons -- grey unreachable, red down, yellow sub-optimal, green healthy -- replacing the Errors, Boards and Status columns. Left-clicking the header cycles the sort through the component facets (overall/power/fans/hashboards); the active facet shows as a tag beside the chevron. Errors move to the cell tooltip. Four operator-supplied Font Awesome icons registered via the existing SVG-in-cell renderer (new SHAPE_BOLT/BRAIN/FAN/CHIP sentinels). #2 Credentials: rename the "Set scan credentials" button to "Credentials" and make the per-firmware defaults the main dialog (the global "all firmwares" login is folded in as the top row). #1 Columns dialog: narrower; new Alphabetical and Categories sort buttons (via a Column::category grouping and a wxbr_reorder_set_order bridge fn); one mouse handler that does both drag-to-reorder and drag-to-rubber-band- select (the old BEGIN_DRAG binding had silently disabled rubber-band selection); Ctrl+A select-all and Ctrl/Shift+Up/Down extend-selection. wx-rs bridge patches 0002/0003 regenerated. Unit tests + headless selftest pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6 |
||
|
|
f1fb2f8623 |
GUI round 12 (#8b, part 2): WhatsMiner control commands on the older V1 backend
asic-rs already implements the full WhatsMiner proprietary control+monitoring surface for V2/V3 (adjust_power_limit, set_led, update_pools, reboot, power_off/ power_on + all reads), so the modern fleet was already covered. The gap was the V1 backend (firmware < 2022-07-29): it declared no control commands, so older units could only be monitored and the GUI's capability actions never appeared. V1-era firmware speaks the same classic btminer token write API as V2 (the round 12 #8b part 1 access-probe handshake proved V1 accepts get_token + AES), so the V1 backend now reuses V2's proven RPC client for writes and implements the same control commands: set_fault_light, set_power_limit, update_pools, restart, pause, resume (HasAuth routes the admin password to the write RPC). Verified live on a V1 unit that the token AES key (password) is accepted; the write path is byte-identical to V2's live-validated one. Some V1 units keep their API in read-only mode and answer writes with Code 45 "can't access write cmd" until an operator enables write access via the WhatsMiner Tool -- a per-device setting; the backend now fails those gracefully instead of hiding the command. 40 whatsminer crate tests pass; GUI self-test passes. Patch queue adds 0007. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Y8h447BPyJR4fioYZvQ9bh |
||
|
|
c8d5cd71c4 |
GUI round 12 (#10): Z15 realtime hashrate + control board, from data we can read
Stock Antminer Z15/Z15J were mis-handled: their control board showed blank and
their realtime hashrate looked absent next to the target. Root cause: the version
detector only read summary.cgi, which the Z15 does not serve (404), so version
detection returned nothing and AntMiner::new fell through to the newest backend,
which mis-parsed the miner. Fixes (all in the vendored asic-rs antminer crate,
verified live on 10.5.1.x):
- Backend routing: fall back to the cgminer :4028 `version` RPC's CompileTime when
summary.cgi is absent, so a 2020 Z15 routes to the v2020 backend instead of the
default newest one.
- Control board "read, not guess": the Z15 has no miner_type.cgi, so read the
control board from the kernel build string in get_system_info.cgi
("Linux 4.6.0-xilinx-..." -> Xilinx). The ControlBoardVersion field now carries
both the subtype and the kernel; the parser prefers the explicit subtype and
falls back to the kernel marker (xilinx/zynq -> Xilinx, aml/meson -> AMLogic).
- Malformed cgminer stats: the Z15 emits a stats array with no commas between its
objects (invalid JSON serde rejected, which dropped every stats-derived field).
Insert the missing separators before parsing (a no-op on valid responses),
restoring expected hashrate, fans, hashboards and uptime. Expected hashrate now
gets the same Equihash Sol/s reinterpretation as the realtime rate, so both read
on one scale (e.g. 144k / 320k) instead of expected reading ~1e6x larger.
Live result: Z15/Z15J now report control board "Xilinx" and realtime/expected
hashrate on the same scale. asic-rs antminer crate tests (35) pass; GUI self-test
passes. Vendored source + refreshed checksum committed; patch queue adds 0006.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Y8h447BPyJR4fioYZvQ9bh
|
||
|
|
8f7aab3f80 |
GUI round 11 (live-miner items #5/#6b/#8/#11): control-board scan gaps, VNish partner build, CVITek PIC bus
All root-caused and fixed against the live fleet (read-only scans; no device state changed). asic-rs changes go through the vendored tree + thirdparty/asic-rs patch queue (0003-0005) with refreshed checksums, per ADR 0003. #5 (XIL/CVITek + WhatsMiner blank control board): - VNish reports the board in short form in /api/v1/info "platform": "cv" (CVITek), "xil" (Xilinx), "aml" (AMLogic); AntMinerControlBoard::parse matched only the full names, so CVITek/Xilinx boards were blank. Added CV/XIL. - Old M30S firmware (< 2022.7.29 -> v1 backend) omits summary's "CB Platform" and v1's parse mandatorily stripped an "ALLWINNER_" prefix. Added get_version /Msg/platform as a fallback source and made the strip optional. - Verified live: S19k Pro cv->CVITek, S19 xil->Xilinx, M30S+ VE40->H6OS. #6b/#11 (VNish partner / shared-devfee build): - The partner build shows as /api/v1/info "build_name" ("WildRose", "vnishreturn"). The VNish backend (v1_2_0 + v1_3_0) now reads /build_name and combines it with the /fw_version number, so firmware_version reads e.g. "WildRose 1.2.7". Verified live on S19j Pro / S19k Pro. #8 (hashboard PIC detection): - pic_probe tried i2c-1/i2c-0 for CVITek, but a live VNish CVITek S19k Pro exposes the hashboard MCU on i2c-3 (i2cdump 0x48 = period-8 -> PIC). Broadened bus_candidates (cvi->[3,4,1,0], aml->[1,3,4,0], bb->[0,1,3,4], else->[1,0,3,4]); probe_pic stops at the first bus that classifies. The classify logic was already correct + unit-tested; only the bus map was wrong. The GUI picks up #5/#6b automatically through asic-rs (CPU/Board columns now populate for VNish CVITek/Xilinx and old M30S; FW Version shows the partner build); #8 is fixed in the GUI's own pic_probe. The miner_probe diagnostic's local-only mutation modes are left uncommitted as before. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Y8h447BPyJR4fioYZvQ9bh |
||
|
|
8eb9a2caad |
GUI round 10 (#8): Z15/Z15J Equihash hashrate shows the correct SI prefix (k, not T)
Root-caused and verified against the live fleet. An Antminer Z15 shows its
hashrate as e.g. "288T" when it is really ~288 kSol/s ("288k"). Equihash miners
report a Sol/s rate in the cgminer "GHS" key, but asic-rs AntMiner parse_hashrate
takes the unit from the key name ("GHS" -> GigaHash), scaling the value 1e9x too
large. The value is a raw Sol/s count, so for Equihash use the base Hash unit;
the toolkit`s SI-prefixing then yields "288k".
Matched by algorithm, and by "Z15" model name for the Z15J (which asic-rs leaves
algo Unknown). Fixed in both the v2020 and v2023_07 AntMiner backends, via
asic-rs patch queue 0002. Verified live: Z15 288T -> ~288k, Z15J 138T -> ~110k.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Y8h447BPyJR4fioYZvQ9bh
|
||
|
|
9e2b453eb5 |
GUI round 9 (#4 v2): WhatsMiner v2 power-limit now reports success on the apply-restart
Follow-up to
|
||
|
|
3530d67a5c |
GUI round 9 (#4): fix WhatsMiner power-limit (v3 auth/param) + asic-rs patch queue
Round-9 #4 -- "the power-limit on the WhatsMiners doesn't apply properly" -- root-caused and verified against the live fleet, then fixed in vendored asic-rs via a new patch queue (ADR 0003). Root cause: asic-rs routes a WhatsMiner to its v3 (WhatsMinerOS) backend when the firmware date is >= 2024-11-01. The v3 privileged power-limit write (command "set.miner.power_limit" on port 4433) authenticated against account "super" but hashed the token with the WEB/admin password, and sent the watt value as a float -- so the miner rejected every write with "invalid json or password is wrong". asic-rs then swallowed that (Ok(data.is_ok()) -> Ok(false)) so the GUI showed "refused" with no reason. (Older miners, fw < 2024-11-01, use the v2 "adjust_power_limit" path, which restarts the miner on a change -- see below.) Fix (thirdparty/asic-rs/patches/0001): - v3 set_auth: the "super" account's token password is a SEPARATE v3 credential (factory default "super"), NOT the web/admin password carried by `auth`; use "super". The web password still drives the v2 (admin) path. - v3 set_power_limit: send the watts as a bare integer (a float trips the firmware's "invalid json" parser). - v2 + v3: propagate the RPC error with `?` instead of swallowing it to Ok(false), so a real failure reaches the round-9 bottom-right error indicator with the miner's own message. Verified on a live M30S+ (fw 20241108, api 3.0.1) via a read-only 4028 capture/restore harness: the fixed request returns {"code":0,"msg":"ok"}; asic-rs set_power_limit now returns Ok(true) and the miner applies the limit (it restarts to re-tune, ~10 min ramp -- expected WhatsMiner behaviour). Matches the pyasic and HashSource whatsminer-api-3 references. All test miners were returned to their prior configured limit. asic-rs patch-queue mechanism (ADR 0003 updated): asic-rs is cargo-vendored, so in-place edits are documented as a numbered patch under thirdparty/asic-rs/ plus a checksum-refresh helper and scripts/apply-asic-rs-patches.sh for re-vendoring. The committed vendor/ tree has the patch applied and its .cargo-checksum.json refreshed, so builds need nothing extra (CI builds fresh; a note documents the local `cargo clean -p` cargo-caching gotcha). Known follow-up: the v2 backend (fw < 2024-11-01) reaches the miner via "adjust_power_limit" but a changed value restarts the miner and the in-restart status check reports failure; whether it applies correctly needs its own verification. The error-propagation change surfaces that honestly meanwhile. Compile-checked (release + tests); 79 offline tests pass. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Y8h447BPyJR4fioYZvQ9bh |