Round 19 #10 telemetry extension. Live-verified against the corpus miners, this
remodels the board temperature thresholds to item #10's target/hot/dangerous scheme
and adds the LuxOS and Braiins backends. Supersedes the ePIC-only critical/shutdown
model shipped in v0.72.0.
Core (asic-rs-core):
- MinerData: temp_critical/temp_shutdown -> temp_target/temp_hot/temp_dangerous.
- parse_temperature_limits (defaulted on the existing GetFluidTemperature trait)
now returns (target, hot, dangerous); parse_data wires all three fields.
Backends (each reads an already-fetched or single command; live-verified):
- LuxOS: new tempctrl RPC; ChipTarget/ChipHot/ChipDangerous (live 10.4.1.60 = 83/93/100).
- Braiins v25_07 + v26_04: configuration/constraints cooling_constraints defaults
(live 10.4.1.83 = 60/80/90); WEB_CONSTRAINTS already fetched for tuning caps.
- ePIC remap: Shutdown Temp -> hot, Critical Temp -> dangerous, no target.
- VNish (settings restart_temp/param) handled in a follow-up (needs settings auth);
Antminer/WhatsMiner expose no thresholds -> (None,None,None).
GUI: the two temp columns (Critical/Shutdown) become three (Target/Hot/Dangerous),
right-aligned, Temperature category, auto-hidden when empty. MinerRow gains
temp_target_c/temp_hot_c/temp_dangerous_c; to_row reads them. ALL_COLUMNS 70 -> 71.
Fixtures captured from live: luxminer tempctrl.json, braiins configuration_constraints.json.
Fixture tests for epic, luxminer, braiins v26_04 assert the parsed thresholds. Patch 0029.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6