- Credentials dialog: new "SSH (restore)" row for the control-board SSH login used by the Braiins restore-to-stock. The username defaults to root; the password is masked and never re-displayed, and a blank password keeps the saved one. Reset to defaults also clears it. ssh-credentials.txt no longer has to be written by hand. - Default scan range is now 192.168.1.1/24 (scans 192.168.1.0/24), and the range dialog's examples use that subnet. - Windows version info, zip README, LICENSE and docs name the publisher as on the signing certificate: BlueFlare Energy Solutions Inc. - Manual updated for all three. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
957 B
957 B
Restore to stock firmware
Restore to stock firmware... removes aftermarket firmware and returns the miner to the manufacturer's firmware it keeps on board. Nothing is uploaded. The miner reboots, and some firmwares come back on a new address.
It is offered when the selection includes a supported firmware, and asks for confirmation with the list of miners first.
| Firmware | How it is removed | Login used |
|---|---|---|
| VNish (and builds based on it) | web API: unlock, then remove firmware; reboots in seconds | the VNish row in Credentials, else admin |
| LuxOS | miner API: log on, then uninstall | none |
| Braiins OS | SSH: runs the firmware's own uninstall.sh |
the SSH row in Credentials (see Settings) |
Miners are restored one at a time. A dropped connection after the command is sent counts as success, because that is the reboot. A refused login counts as a failure and leaves the miner unchanged.