Round 19 #10 / #8 telemetry extension. Adds the fan duty cycle as a miner-level
percentage -- the normalized fan-load indicator the GUI wanted alongside per-fan
RPMs. No firmware exposes a maximum fan RPM, so a true actual/maximum pair is not
possible; the duty cycle is the closest normalized signal.
Core (asic-rs-core):
- New DataField::FanSpeedPercent; MinerData gains fan_speed_percent (Option<f64>).
- Modeled as a top-level miner-level value (most firmwares report a single duty),
so FanData is untouched -- no Eq removal / literal churn across its 17 crates.
- Rides the existing GetFans trait via a defaulted parse_fan_speed_percent method
(no supertrait blast radius); parse_data wires it in.
Backends (read already-fetched commands, no extra round-trips):
- ePIC: summary /Fans/Fans Speed (single %).
- LuxOS: max of FANS[].Speed.
- Braiins v25_07 + v26_04: max of cooling fans[].target_speed_ratio x 100.
- Antminer (pwm via config) and VNish (fan_duty) have no data fixtures -> left for a
live-verified pass; WhatsMiner is firmware-locked -> None.
GUI: new "Fan %" column (right-aligned, Cooling category, auto-hidden when empty).
MinerRow gains fan_speed_percent; to_row reads it. ALL_COLUMNS 67 -> 68.
Fixture tests: epic, luxminer, braiins v26_04 assert the parsed percentage. Patch 0027.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6