Files
BFE Engineering 42fb386f60 docs: ASCII typography and style normalization across all repo text
Replace every em dash with real punctuation (rewrites, not hyphen swaps)
in docs, code comments, scripts, configs, and the port records; convert
en dashes, curly quotes, ellipsis glyphs, arrows, and section signs to
ASCII; drop machine-writing tell phrases from living docs. ADR titles
now use a colon. The M2 bring-up DTS model string carried an em dash
into the patch series and its record echoes; fixed at both, and the full
series re-verified to apply cleanly onto pristine 6.18.46. One comment
in freshness.h deliberately names the em dash glyph the UI renders as
the unknown mark; that is data, kept as prose naming it.

Verified: cargo tests (sim, config-lint, rs485-bridge), shellcheck,
both driver MC/DC harnesses, patches-apply.
2026-08-31 12:31:27 -06:00

2.0 KiB

TRNG + OTP port (batch A): 6.18

TRNG (hardware RNG): VERIFIED on warden-c8a3 (2026-08-25)

rv1106's rockchip,trngv1 is the same standalone TRNG_V1 IP as rk3588 (identical register map). Mainline drivers/char/hw_random/rockchip-rng.c already drives it.

Delta: one OF-table entry reusing rk3588_soc_data:

{ .compatible = "rockchip,rv1106-rng", .data = (void *)&rk3588_soc_data },

(The driver grabs clocks via clk_bulk_get_all and treats reset as optional, so rv1106's clock/reset names need no special handling.) Kconfig HW_RANDOM_ROCKCHIP=y (already set).

DT (rv1106-warden.dts): override the dtsi rng@ff448000 node:

&rng { compatible = "rockchip,rv1106-rng"; status = "okay"; };

Evidence: /dev/hwrng present, rng_current = rockchip-rng, dd if=/dev/hwrng bs=16 -> c697 503d f9db 6b84 50e4 e1ee f232 b2ae (real HW entropy, non-zero). Hardware entropy source for the panel's crypto/keys.

OTP / nvmem: VERIFIED on warden-c8a3 (2026-08-25)

Reads real data: dd .../rockchip-otp0/nvmem bs=1 count=16 | xxd -> 5211 02fe 084d 5231 0000 0000 3b15 0000 (contains "MR1" chip id), no timeout. Mainline drivers/nvmem/rockchip-otp.c gains an rv1106_data + compatible.

Delta:

static const char * const rv1106_otp_clocks[] = {
	"usr", "sbpi", "apb", "phy", "arb", "pmc",   /* matches DT clock-names */
};
static const struct rockchip_data rv1106_data = {
	.size = 0x80,
	.clks = rv1106_otp_clocks,
	.num_clks = ARRAY_SIZE(rv1106_otp_clocks),
	.reg_read = px30_otp_read,     /* user-mode OTPC_USER interface */
};
/* OF: { "rockchip,rv1106-otp", &rv1106_data } */

Kconfig NVMEM_ROCKCHIP_OTP=y. DT: &otp { status = "okay"; }; (the dtsi otp@ff3d0000 node already carries compatible + the 6 clocks/resets).

First try used .reg_read = rk3588_otp_read -> timeout during read setup (rk3588 uses a different addressing path). Corrected to px30_otp_read: the mainline user-mode OTPC_USER read, the same sequence the vendor 5.10 driver used for rv1106 (its rk3568_otp_read). Confirmed: cell reads return real data.