Document miner work ID and shutdown guards
main-release-gate / verify-and-release (push) Failing after 3m25s

This commit is contained in:
2026-10-15 13:04:44 -06:00
parent ebea5f5cfd
commit b1eb641729
+3
View File
@@ -87,6 +87,9 @@ When the 32 hardware work IDs are exhausted, the client checks temperature,
resets the chain, discards old reports, and only then reuses an ID for the next
job. A reset failure requests PSU shutdown. A host test dispatches 33 jobs
and checks the reset boundary; sustained board operation is still unverified.
The miner also reserves each work ID until a confirmed chain reset or PSU
shutdown, even after a pool clean-jobs message. A failed PSU-off call faults
the miner and blocks further work until a shutdown retry succeeds.
The executable still lacks a board adapter and run loop.
The Stratum V1 decoder bounds and validates `mining.subscribe` responses,
nine-field Bitcoin `mining.notify` jobs, difficulty and extranonce changes,