Compare commits

...
1 Commits
Author SHA1 Message Date
noahandClaude Opus 4.8 93bd528430 health: PSU-fault colour rules + per-board actual/expected tooltip (round 18 #2/#3/#4b)
- #2 A PSU fault while the miner is mining is now a warning (yellow) not a failure
  (red); a fault on a non-mining miner stays red. Fixes WhatsMiners flagged red
  while running fine.
- #4b A PSU fault no longer greys the hashboards. Board colour reflects the board's
  own state: running -> green, faulted (e.g. WhatsMiner 540/560) -> red, and grey
  ONLY when the board is genuinely not detected. Stall-reddened boards the fault
  codes don't name are still exonerated to green; undetected boards stay grey.
- #3 The per-board tooltip shows actual / expected hashrate (e.g. "2  .  33.5 / 35.0
  TH/s"); a not-detected board shows "not detected". Adds MinerRow.board_expected_
  hashrates (from BoardData.expected_hashrate) + an algorithm-aware hashrate unit
  (Equihash -> Sol/s, groundwork for #7).

Health tests updated + pass; SELFTEST PASS.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Djv3oncM4LxTS5tb61Ako6
2026-09-22 16:36:00 -06:00
2 changed files with 84 additions and 32 deletions
+71 -32
View File
@@ -420,6 +420,10 @@ pub struct MinerRow {
/// = board 1). Drives the per-board Health tooltip (round 17 R2). Empty when
/// the firmware reports no per-board hashrate.
pub board_hashrates: Vec<f64>,
/// Per-hashboard EXPECTED hashrate in TH/s, index-aligned with the hashboards.
/// The per-board tooltip shows actual / expected (round 18 #3). Empty when the
/// firmware reports no per-board expected hashrate.
pub board_expected_hashrates: Vec<f64>,
#[allow(dead_code)] // retained for the "slow" band; not shown as its own column
pub efficiency: f64,
pub power_w: f64,
@@ -516,12 +520,17 @@ impl MinerRow {
/// live); grey (unknown) otherwise -- asic-rs has no direct PSU-fault flag, so
/// a missing wattage reading is treated as unknown, never a false "down".
pub fn power_health(&self) -> CompHealth {
// A reported power-supply fault (round 16 #2) is authoritative: red, even
// if a residual wattage is still being read.
// A miner drawing power / spinning its PSU fan / actively mining has a live
// PSU regardless of any warning flag.
let delivering = self.power_w > 0.0 || self.psu_fan_rpm > 0.0 || self.is_mining;
// A reported PSU fault while the miner is actually mining is a warning, not
// a failure -- yellow, not red (round 18 #2: some WhatsMiners flag a PSU
// error while running fine). A fault on a miner that is not mining is a real
// failure (red).
if self.faults_for(FaultComponent::Power).next().is_some() {
return CompHealth::Down;
return if self.is_mining { CompHealth::Degraded } else { CompHealth::Down };
}
if self.power_w > 0.0 || self.psu_fan_rpm > 0.0 || self.is_mining {
if delivering {
CompHealth::Ok
} else {
CompHealth::Unreachable
@@ -557,12 +566,6 @@ impl MinerRow {
.filter(|f| f.is_error && matches!(f.component, FaultComponent::Other))
}
/// True when the miner reports a power-supply fault, which means the
/// hashboards cannot be powered or evaluated (round 16 #2).
fn power_supply_faulted(&self) -> bool {
self.faults_for(FaultComponent::Power).next().is_some()
}
/// Per-fan health (round 13 #3), front-to-back / top-to-bottom in the order
/// the miner reports its fans. A spinning fan is green, unless it is running
/// well below its fastest sibling (< 50% of the max reported RPM), which is a
@@ -621,16 +624,22 @@ impl MinerRow {
if base.is_empty() {
return base;
}
// 3. A PSU fault means no board can be powered/tested -> all grey.
if self.power_supply_faulted() {
return vec![CompHealth::Unreachable; base.len()];
}
// 2. Board-specific faults are authoritative: red only the named boards,
// green the rest (overriding a stall-induced all-red).
// 2. Board-specific faults are authoritative: red the named boards. A board
// is grey ONLY when it is genuinely not detected (base Missing); a board
// that is running stays green and a faulted board is red, even when the
// PSU also reports a fault (round 18 #4b -- WhatsMiner codes 540/560 must
// show red, not grey, and boards still hashing during a PSU fault stay
// green). A whole-miner stall reds every board's base, so exonerate the
// boards the fault codes did NOT name back to healthy.
let board_faulted = |i: usize| self.faults_for(FaultComponent::Board(i)).next().is_some();
if (0..base.len()).any(board_faulted) {
for (i, h) in base.iter_mut().enumerate() {
*h = if board_faulted(i) { CompHealth::Down } else { ok };
if board_faulted(i) {
*h = CompHealth::Down;
} else if *h == CompHealth::Down {
*h = ok; // stall-reddened but not named by the fault codes
}
// else keep the base (green Ok / grey Missing).
}
}
base
@@ -736,22 +745,26 @@ impl MinerRow {
tips.push(t);
}
// Hashboards -- an operating board shows its number (counting DOWN, n-1..0,
// left to right) and hashrate; a faulted board shows its error+code; a
// board the failed PSU left untested shows "unpowered" (round 17 R2,
// round 16 #2/#3). No generic "Hashboard N: faulted" prose.
// left to right) and actual/expected hashrate; a faulted board shows its
// error+code; a board that is genuinely not detected shows "not detected"
// (round 17 R2, round 18 #3 actual/expected + #4b). No generic
// "Hashboard N: faulted" prose.
let boards = self.board_healths();
let psu_down = self.power_supply_faulted();
let n = self.hashboards.map(|v| v as usize).unwrap_or(boards.len());
let unit = self.hashrate_unit();
for i in 0..max_boards {
let fault = self.fault_texts_for(FaultComponent::Board(i));
let t = if !fault.is_empty() {
fault.join("\n")
} else if matches!(boards.get(i), Some(CompHealth::Unreachable)) && psu_down {
"unpowered (PSU fault)".to_string()
} else if matches!(boards.get(i), Some(CompHealth::Unreachable)) {
"not detected".to_string()
} else if i < n {
let num = n - 1 - i; // count down, left to right
match self.board_hashrates.get(i).copied() {
Some(hr) if hr > 0.0 => format!("{num} \u{00b7} {hr:.1} TH/s"),
let actual = self.board_hashrates.get(i).copied().unwrap_or(0.0);
let expected = self.board_expected_hashrates.get(i).copied().unwrap_or(0.0);
match (actual > 0.0, expected > 0.0) {
(true, true) => format!("{num} \u{00b7} {actual:.1} / {expected:.1} {unit}"),
(true, false) => format!("{num} \u{00b7} {actual:.1} {unit}"),
_ => num.to_string(),
}
} else {
@@ -773,6 +786,17 @@ impl MinerRow {
}
}
/// The display unit for this miner's hashrate, by mining algorithm (round 18
/// #7). SHA256/Scrypt miners report TH/s; Equihash miners (Antminer Z15 /
/// Zcash) report in Sol/s and must not be labelled TH/s.
pub fn hashrate_unit(&self) -> &'static str {
if self.algorithm.eq_ignore_ascii_case("equihash") {
"Sol/s"
} else {
"TH/s"
}
}
/// Compact plain-text summary of component health (round 13 #3), used as the
/// Health column's filter/sort-fallback text and the base of its hover
/// tooltip. e.g. "power ok, fans 3/4, boards 3/3".
@@ -1743,22 +1767,37 @@ mod tests {
assert!(board_tips[0].contains("Slot 0 error reading chip id."));
assert!(!board_tips[2].contains("Slot"), "board 3 has no fault text");
// Round 16 #2: a power-supply fault greys every board (they can't be
// powered/tested), turns the bolt red, and the PSU message shows on the
// power tooltip.
// Round 18 #2/#4b: a PSU fault while the miner is NOT mining is a real
// failure (red bolt), and boards keep their own reported state -- a PSU
// fault no longer greys them. Faulted boards stay red.
let psu = MinerRow {
power_w: 40.0,
board_status: vec![BoardHealth::Fault, BoardHealth::Fault, BoardHealth::Fault],
expected_fans: Some(2),
fan_rpms: vec![6000.0, 6000.0],
faults: vec![fault(FaultComponent::Power, "Power current error.")],
..Default::default()
..Default::default() // is_mining = false
};
assert_eq!(psu.power_health(), CompHealth::Down);
assert!(psu.board_healths().iter().all(|h| *h == CompHealth::Unreachable));
assert_eq!(psu.power_health(), CompHealth::Down); // fault + not mining -> red
assert!(psu.board_healths().iter().all(|h| *h == CompHealth::Down)); // faulted -> red, not grey
let ptips = psu.health_tooltips(2, 3);
assert!(ptips[0].contains("Power current error."));
assert!(ptips[2 + 2].contains("unpowered")); // first board tooltip
// Round 18 #2: the SAME PSU fault while the miner IS mining is a warning
// (yellow bolt), and running boards stay GREEN (not grey). Round 18 #4b:
// grey is reserved for genuinely-undetected boards.
let psu_running = MinerRow {
is_mining: true,
power_w: 3000.0,
board_status: vec![BoardHealth::Ok, BoardHealth::Ok, BoardHealth::Missing],
faults: vec![fault(FaultComponent::Power, "Power vout warning.")],
..Default::default()
};
assert_eq!(psu_running.power_health(), CompHealth::Degraded); // yellow, not red
let rb = psu_running.board_healths();
assert_eq!(rb[0], CompHealth::Ok); // running -> green despite PSU fault
assert_eq!(rb[1], CompHealth::Ok);
assert_eq!(rb[2], CompHealth::Unreachable); // only the undetected board is grey
}
#[test]
+13
View File
@@ -614,6 +614,18 @@ async fn to_row(miner: &dyn Miner) -> MinerRow {
.unwrap_or(0.0)
})
.collect();
// Per-board expected hashrate (TH/s), index-aligned, for the actual/expected
// per-board tooltip (round 18 #3).
let board_expected_hashrates: Vec<f64> = data
.hashboards
.iter()
.map(|b| {
b.expected_hashrate
.as_ref()
.map(|h| h.clone().as_unit(asic_rs::core::data::hashrate::HashRateUnit::TeraHash).value)
.unwrap_or(0.0)
})
.collect();
let fan_rpms: Vec<f64> = data
.fans
.iter()
@@ -843,6 +855,7 @@ async fn to_row(miner: &dyn Miner) -> MinerRow {
hashrate_ths,
expected_ths,
board_hashrates,
board_expected_hashrates,
efficiency: data.efficiency.unwrap_or(0.0),
power_w,
// PSU info (round 17 R5/G15; ePIC exposes it today). A reported-but-zero