flare-edge#351 moves the panel's warden-modbus to S21modbus and warden-automation to S22automation, right after S20linkmount, so a relay held by an autostart automation closes about 9 s sooner on every reboot or OTA. An automation's device command goes through warden-modbus (flare-edge#331), so modbus starts first, and rcK stops it after automation.
The rig's /sbin/init starts the same daemons "in their S-number order" but listed automation before modbus (the old S93 and S94). It now starts modbus, then automation, then ai, mikrotik, asic, starlink, stratum and flared, and the comment names the new numbers.
Test
qemu/tests/init-daemon-order-test.sh (new, wired into CI) reads the init script's start loop and pins that order. Revert proof: with the old sbin/init it fails and shows modbus and automation swapped. With the change it passes. shellcheck is clean on both files.
Not merging: flare-edge#351 bumps the submodule to this branch once it is reviewed.
Part of flare-edge#348 (flare-edge PR #351).
flare-edge#351 moves the panel's warden-modbus to `S21modbus` and warden-automation to `S22automation`, right after `S20linkmount`, so a relay held by an autostart automation closes about 9 s sooner on every reboot or OTA. An automation's device command goes through warden-modbus (flare-edge#331), so modbus starts first, and rcK stops it after automation.
The rig's `/sbin/init` starts the same daemons "in their S-number order" but listed automation before modbus (the old S93 and S94). It now starts modbus, then automation, then ai, mikrotik, asic, starlink, stratum and flared, and the comment names the new numbers.
## Test
`qemu/tests/init-daemon-order-test.sh` (new, wired into CI) reads the init script's start loop and pins that order. Revert proof: with the old `sbin/init` it fails and shows modbus and automation swapped. With the change it passes. shellcheck is clean on both files.
Not merging: flare-edge#351 bumps the submodule to this branch once it is reviewed.
Generated with [Claude Code](https://claude.com/claude-code)
https://claude.ai/code/session_01441BzdGcvQmXkiN2qDjfZg
flare-edge#348 moves the panel's warden-modbus to S21modbus and
warden-automation to S22automation, right after S20linkmount, so a held
relay closes about 9 s sooner at boot. An automation's device command
goes through warden-modbus (flare-edge#331), so modbus starts first. The
rig's init starts the same daemons in the panel's S-number order and
listed automation before modbus (S93, S94); it now matches the panel.
init-daemon-order-test.sh reads the start loop and pins the order; it
fails on the old list. Wired into CI.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01441BzdGcvQmXkiN2qDjfZg
noah
merged commit d01add5646 into flare-edge-next2026-10-02 23:05:17 -06:00
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Part of flare-edge#348 (flare-edge PR #351).
flare-edge#351 moves the panel's warden-modbus to
S21modbusand warden-automation toS22automation, right afterS20linkmount, so a relay held by an autostart automation closes about 9 s sooner on every reboot or OTA. An automation's device command goes through warden-modbus (flare-edge#331), so modbus starts first, and rcK stops it after automation.The rig's
/sbin/initstarts the same daemons "in their S-number order" but listed automation before modbus (the old S93 and S94). It now starts modbus, then automation, then ai, mikrotik, asic, starlink, stratum and flared, and the comment names the new numbers.Test
qemu/tests/init-daemon-order-test.sh(new, wired into CI) reads the init script's start loop and pins that order. Revert proof: with the oldsbin/initit fails and shows modbus and automation swapped. With the change it passes. shellcheck is clean on both files.Not merging: flare-edge#351 bumps the submodule to this branch once it is reviewed.
Generated with Claude Code
https://claude.ai/code/session_01441BzdGcvQmXkiN2qDjfZg