init-power-signals-test.sh slept a fixed 0.5 s before sending each signal.
On a loaded runner the shell had not installed its traps yet, so SIGTERM
took its default action and the case failed with nothing written.
Each case now polls /proc/<pid>/status until SigCgt has the signal's bit
(10 s hang backstop, WARDEN_TEST_TRAP_WAIT_S), and fails clearly if the
handler never appears. Regression: a case whose handler install is held
back 1.5 s (fails on the old fixed sleep), plus a check that the wait gives
up on a shell without a handler.
Fixes#22
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01KerYPVh72hhNgKi3wS5ijG