Files
bfe-core1106-sdk/kernel/rv1106-enablement/rng-otp/PORT-DONE.md
T
BFE EngineeringandClaude Opus 4.8 270211029d kernel/rv1106: batch A — TRNG verified + OTP (read fn corrected)
TRNG  VERIFIED on c8a3: rv1106 trngv1 == rk3588 TRNG_V1 IP; one OF-table
entry reusing rk3588_soc_data. /dev/hwrng active, rng_current=rockchip-rng,
real HW entropy (c697503d... non-zero). Hardware entropy for the panel.

OTP 🔨: rockchip-otp0 nvmem device registers; added rv1106_data (6-clock
sbpi layout). First reg_read=rk3588_otp_read timed out ('timeout during read
setup'); corrected to px30_otp_read (user-mode OTPC_USER interface = the
vendor's rk3568_otp_read sequence). Cell reads re-verify next _b boot.

See rng-otp/PORT-DONE.md. dts snapshot refreshed (rng+otp enabled).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_017wB8KB3MMQztRDXCMCkPrf
2026-08-25 00:44:35 -06:00

48 lines
2.0 KiB
Markdown

# TRNG + OTP port (batch A) — 6.18
## TRNG (hardware RNG) — ✅ VERIFIED on warden-c8a3 (2026-08-25)
rv1106's `rockchip,trngv1` is the same standalone TRNG_V1 IP as rk3588 (identical
register map). Mainline `drivers/char/hw_random/rockchip-rng.c` already drives it.
**Delta:** one OF-table entry reusing `rk3588_soc_data`:
```c
{ .compatible = "rockchip,rv1106-rng", .data = (void *)&rk3588_soc_data },
```
(The driver grabs clocks via `clk_bulk_get_all` and treats reset as optional, so
rv1106's clock/reset names need no special handling.) Kconfig
`HW_RANDOM_ROCKCHIP=y` (already set).
**DT** (`rv1106-warden.dts`): override the dtsi `rng@ff448000` node —
```dts
&rng { compatible = "rockchip,rv1106-rng"; status = "okay"; };
```
**Evidence:** `/dev/hwrng` present, `rng_current = rockchip-rng`,
`dd if=/dev/hwrng bs=16``c697 503d f9db 6b84 50e4 e1ee f232 b2ae` (real HW
entropy, non-zero). Hardware entropy source for the panel's crypto/keys.
## OTP / nvmem — 🔨 device registers; read fn corrected, re-verify pending
Mainline `drivers/nvmem/rockchip-otp.c` gains an `rv1106_data` + compatible.
**Delta:**
```c
static const char * const rv1106_otp_clocks[] = {
"usr", "sbpi", "apb", "phy", "arb", "pmc", /* matches DT clock-names */
};
static const struct rockchip_data rv1106_data = {
.size = 0x80,
.clks = rv1106_otp_clocks,
.num_clks = ARRAY_SIZE(rv1106_otp_clocks),
.reg_read = px30_otp_read, /* user-mode OTPC_USER interface */
};
/* OF: { "rockchip,rv1106-otp", &rv1106_data } */
```
Kconfig `NVMEM_ROCKCHIP_OTP=y`. **DT:** `&otp { status = "okay"; };` (the dtsi
`otp@ff3d0000` node already carries compatible + the 6 clocks/resets).
**First try** used `.reg_read = rk3588_otp_read``timeout during read setup`
(rk3588 uses a different addressing path). Corrected to `px30_otp_read` — the
mainline user-mode OTPC_USER read, the same sequence the vendor 5.10 driver used
for rv1106 (its `rk3568_otp_read`). Re-verify cell reads on the next _b boot;
`rockchip-otp0` nvmem device already registers.